Sign In | Join Free | My himfr.com
Home > Telecom Battery >

38V 100AH Lithium Ion Battery For Telecom Application 19 ”Standard Cabinet

    Buy cheap 38V 100AH Lithium Ion Battery For Telecom Application 19 ”Standard Cabinet from wholesalers
     
    Buy cheap 38V 100AH Lithium Ion Battery For Telecom Application 19 ”Standard Cabinet from wholesalers
    • Buy cheap 38V 100AH Lithium Ion Battery For Telecom Application 19 ”Standard Cabinet from wholesalers

    38V 100AH Lithium Ion Battery For Telecom Application 19 ”Standard Cabinet

    Ask Lasest Price
    Model Number : TL38100LFP-3U
    Price : Negotiable
    Delivery Time : 30 DAYS
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 1800000 PCS/YEAR
    • Product Details
    • Company Profile

    38V 100AH Lithium Ion Battery For Telecom Application 19 ”Standard Cabinet

    38V 100AH 19”Standard Cabinet Suited Rechargeable Lithium Ion (LiFePO 4 ) Battery Pack


    • Product Overview

    The 38V Lithium Ion Battery Pack is mainly working as 38VDC backup power source, and it consists

    of 12 cells of Lithium Iron Phosphate Battery Cells connected in series and telecom specialized high

    performance and high reliability Battery Management System (BMS). The battery’s +/- output terminals

    are connected to the +/- terminals of rectifier. When the mains supply is normal, telecom equipment is

    powered by mains through rectifier and battery pack is also charged through rectifier; When the mains

    supply is outage, the 38V lithium ion battery pack is supplying power to telecom equipment without any

    time-delay to ensure telecom equipment is powered without any interruptions, until mains supply

    resumed or protective power cut-off by BMS due to over-discharge protection activated automatically.​


    • Features and Benefits​

    - Voltage detection and protection function

    The Product has the functions of cell and module voltage detection, over voltage, under voltage alarm

    and protection. The cell voltage detection accuracy is less than ± 15mV under normal temperature static

    conditions.

    - Current detection and protection function

    The Product has the functions of charge and discharge current detection, alarming and protection. The

    charging current is shown as a positive current and the discharge current is shown as a negative current.

    The current sampling accuracy is less than ± 2% under normal temperature conditions.

    - Temperature detection and protection function

    With the function of cell and environment temperature detection, when the temperature is too high or too

    low the product will start up alarming and protection function. The temperature sampling accuracy is less

    than ±2°C within the operating temperature range. Four battery temperature detection points and one

    ambient temperature detection point (maximum 16 battery temperature detection points) are supported

    by default.

    - Short-circuit protection function

    With short-circuit protection function, the short circuit delay time can be set by the host computer. The

    short circuit current should be less than 1200A.

    - Battery capacity calculation function

    Cell algorithm: About the use of soc and soh, soc uses the basic elements of the Ampere integration and

    OCV method. The Ampere integration method and voltage, by the adjustment of the algorithm, with higher

    precision data and Independent clock system, ensures reasonable display during a single cycle. And the

    SOC estimation accuracy is ≤ ± 8%


    • Product Specification​

    Product Working Principal

    Electrical Specification


    ItemSpecificationRemarks
    Nominal Capacity100AhStandard discharge (1) capacity after standard charge (2)
    Nominal Voltage3 8.4VConfiguration: 12S2P - VHR 3914895LFP-50Ah. Voltage of single cell is 3.2V.
    Charge Voltage43.2V 
    Voltage at End of Discharge33.0V 
    Floating Voltage40.0V 
    Maximum Continuous Charge Current (CC Threshold)100A 
    Over Current Protection for Charge105AN.A.
    Over Voltage Protection3.80V/cellN.A.
    Maximum Continuous100A 
    Discharge Current
    Over Current Protection for Discharge105AN.A.
    Under Voltage Protection2.75V/cellN.A.
    Operation AllowableCharge: 0~60°CN.A.
    Temperature RangeDischarge: -20~60°CN.A.
    Continuous Discharge Power0.76kW50%SOC
    Continuous Charge Power0.76kWN.A.
    Self-discharge Rate/Month≤3%@ 25 ± 3℃,50%SOC
    Cycle Life(cycles)≥5000@ 25 ± 3℃,80%DOD, 0.2C/0.2C
    Operation Allowable≤95% RHOperation
    Humidity Range≤85% RHStorage
    Recommended0~40°CMax. 6 month
    Storage temperature
    WeightAbout 37kgN.A.

    • Dimension


    • Basic Parameter
    ItemSettableDetailed InformationDefault Setting ValueRemark
    (Yes or No)
    Charge Current LimitNoLimited Charge Current Value105AAcceptability range:105 ± 2A
    YesMethod of Charge Current LimitOverchargeactivates current limitN.A.
    Sleep VoltageYesSleep Voltage Set Value3.30 VAcceptability range: 3.3 ± 0.02V
    BMS Power consumptionNoInternal Circuit Power Consumption at Mode 1 – Fan is not activated or for natural cooling model with heat radiator≤ 40 mAN.A.
    NoInternal circuitpower consumption during sleep≤ 500 uA
    Charge BalancingYesBalancing Activation Voltage Value3.40 VN.A.
    YesBalancing Activation Voltage Difference Value50 mV
    NoBalancing current70 mA
    Full Charge SettingYesConstant voltage value43.2 ± 0.3VDuring constant voltage charging, when the overall voltage is greater than the constant voltage and the current is less than the constant current value, the BMS will assume that the battery capacity is fully charged and the charging MOSFET will be cut off.
    YesConstant current value5.0A
    Standby TimeNoInterval days of forced recovery charge after overcharge0In order to ensure the battery capacity, after the battery over-voltage protection, the battery will be forced to resume charging after a fixed time; when the time is configured to 0, this function does not work.
    Under-voltage OFF TimeNoDischarge MOS turn-on interval time after undervoltage0In order to be compatible with the traditional lead-acid charger charging method, the BMS periodically closes the discharge MOSFET for about 7.5 seconds after undervoltage protection, so that the charger detects the battery voltage and turns on the charging. The interval period of the closed discharge MOSFET can be set. When configured to 0, this function does not work.
    Capacity SettingYesFull capacity setting100AhN.A.
    YesResidual capacity setting50Ah

    • Indicators Illustration

    A) SOC Indication

    B) Other LED Indication

    Pack StatusProtect /Alarm /NormalRUNALMSOC LEDDescription
    ——
    Power down/Sleep——OFFOFFOFFOFFOFFOFF——
    StandbyNormalFlash 1OFFAccording to the SOC——
    ChargeNormalFlash 2OFFAccording to the SOC——
    DischargeNormalONOFFAccording to the SOC——
    Charge / Discharge / StandbyProtectAccording to the state of charge and dischargeFlash 2According to the SOC——
    Charge / Discharge / StandbyAlarmOFFONOFF——

    C) LED Flash State


     LightExtinguish
    Flash10.25S3.75S
    Flash20.5S0.5S
    Flash30.5S1.5S

    • Cautions

    - Please read the user manual carefully before using the lithium ion battery.

    - No human body shall direct contact the positive/negative poles at the same time if the battery’s voltage exceeds 36V safety

    voltage.

    - Please read the specific charging device’s user manual carefully before charging.

    - When the battery is not charged after long exposure to the charger, discontinue charging.

    - Please check the positive (+) and negative (-) direction before connection.

    - Battery must be stored in a dry area with low temperature (≤25°C) environment for long-term storage.

    - Do not expose the battery in direct sunlight or heat.

    - Do not use the battery in high static energy environment where the protection device can be damaged.

    - When rust or smell is detected on first use, please return the product to the seller immediately.

    - Keep the battery out of reach of children and pets.

    - When battery life span shortens after long period of usage, please exchange to new battery.

    - No metal objects (rings, watches, and other metal accessories, etc.) can be worn during the handling of battery.

    - Charge time should not be longer than specified in the manual.

    - Do not expose the battery out of the temperature range specified in the specification.


    Quality 38V 100AH Lithium Ion Battery For Telecom Application 19 ”Standard Cabinet for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Zhejiang Hengrui Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)